Hrvatski normativni dokument

HRN EN 15058:2008

Emisije iz stacionarnih izvora -- Određivanje masene koncentracije ugljik monoksida (CO) -- Referentna metoda -- Nedisperzivna infracrvena spektrometrija (EN 15058:2006)

Oznaka: HRN EN 15058:2008
Naslov (HR): Emisije iz stacionarnih izvora -- Određivanje masene koncentracije ugljik monoksida (CO) -- Referentna metoda -- Nedisperzivna infracrvena spektrometrija (EN 15058:2006)
Naslov (EN): Stationary source emissions -- Determination of the mass concentration of carbon monoxide (CO) -- Reference method -- Non-dispersive infrared spectrometry (EN 15058:2006)
Područje primjene (EN): This European Standard specifies the Standard Reference Method (SRM) for sampling, and determining car-bon monoxide content in ducts and stacks emitting to atmosphere. It describes the Non Dispersive Infra-Red (NDIR) analytical technique, including the sampling system and sample gas conditioning system, to determine CO in flue gases. This European Standard is the reference method for periodic monitoring and for calibration or control of Automatic Measuring Systems (AMS) permanently installed on a stack, for regulatory purposes or other purposes. To be used as the SRM, it is necessary to demonstrate that the performance characteristics of the method are lower than the performance criteria defined in this European standard and that the overall uncertainty of the method is less than ± 6 % relative at the daily Emission Limit Value (ELV).
NOTE When the NDIR method is used as an AMS, refer to EN 14181 and other relevant standards provided by CEN TC 264.
It is necessary for anybody who would like to use an Alternative Method instead of this Standard Reference Method to work out the demonstration of the equivalence according to the Technical Specification TS 14793, providing that his capability to carry out this demonstration is officially recognised by his national accreditation body or law.
This Standard Reference Method has been evaluated during field tests on waste incineration, co-incineration installations and large combustion plants. It has been validated for CO concentrations with sampling periods of 30 min in the range of 0 mg/m3 to 400 mg/m3 for large combustion plants and 0 mg/m3 – 740 mg/m3 for waste and co-incineration. For waste incineration plants, Council Directive 2000/76/EC lays down emission values which are expressed in mg/m3, on dry basis at a specified value of O2 and at reference conditions of 273 K and 101,3 kPa.
Izdanje: 1
ICS: 13.040.40 Emisije iz stacionarnih izvora
Tehnički odbor/pododbor: TO 146, Kvaliteta zraka
Oznaka faze: 95.99 - povlačenje HRN
Glasilo (rasprava): HZN Glasilo 4/2008 ()
Glasilo (objava): HZN Glasilo 5/2008 ()
Glasilo (povlačenje): 1/2017 ()
Način prihvaćanja: pr - prihvaćanje strane norme u izvorniku
Cijena #1: Cijena: 48,00 € | Jezik: en | Cjenovni razred: I | Broj stranica: 42
Izvornik: EN 15058:2006
Zamjenjena s: HRN EN 15058:2017

Obrazac za naručivanje normativnih dokumenata i/ili publikacija (obrazac ob.025-2):

PREUZMITE (DOC)   PREUZMITE (PDF) 

Prijava korisnika

Mrežna stranica koristi kolačiće (cookies). Kolačiće upotrebljavamo kako bismo personalizirali sadržaj i oglase, omogućili značajke društvenih medija i analizirali promet. Isto tako, podatke o vašoj upotrebi naše web-lokacije dijelimo s partnerima za društvene medije, oglašavanje i analizu, a oni ih mogu kombinirati s drugim podacima koje ste im pružili ili koje su prikupili dok ste upotrebljavali njihove usluge. Nastavkom korištenja naših internetskih stranica vi prihvaćate našu upotrebu kolačića. Polica privatnosti.