HRN EN 50600-1:2013

Informacijska tehnologija -- Sredstva i infrastrukture podatkovnih centara -- 1. dio: Opći koncepti (EN 50600-1:2012)

Oznaka: HRN EN 50600-1:2013
Naslov (HR): Informacijska tehnologija -- Sredstva i infrastrukture podatkovnih centara -- 1. dio: Opći koncepti (EN 50600-1:2012)
Naslov (EN): Information technology -- Data centre facilities and infrastructures -- Part 1: General concepts (EN 50600-1:2012)
Područje primjene (EN): This European Standard: a) details the issues to be addressed in a business risk and operating cost analysis enabling application of an appropriate classification of the data centre, b) defines the common aspects of data centres including terminology, parameters and reference models (functional elements and their accommodation) addressing both the size and complexity of their intended purpose, c) describes general aspects of the facilities and infrastructures required to support effective operation of telecommunications within data centres, d) specifies a classification system, based upon the key criteria of “availability”, “security” and “energy-efficiency” over the planned lifetime of the data centre, for the provision of effective facilities and infrastructure, e) describes the general design principles for data centres upon which the requirements of the EN 50600 series are based including symbols, labels, coding in drawings, quality assurance and education, The following topics are outside of the scope of this series of European Standards: 1) the selection of information technology and network telecommunications equipment, software and associated configuration issues are outside the scope of this European Standard; 2) safety and electromagnetic compatibility (EMC) requirements (covered by other standards and regulations. However, information given in this European Standard may be of assistance in meeting these standards and regulations). 1.2 Conformance For a data centre design to conform to this European Standard: a) a business risk analysis according to Clause 4 shall be done, b) an appropriate Availability Class in 6.2 shall be selected using a business risk analysis in Clause 4, c) an appropriate Protection Class in 6.3 shall be selected using a business risk analysis in Clause 4, d) an appropriate energy efficiency enablement level in 6.4 shall be selected, e) the general design principles in Annex A shall be applied.
Izdanje: 1
ICS: 35.020 Informacijska tehnologija (IT) općenito
35.160 Mikroprocesorski sustavi
Tehnički odbor/pododbor: TO E502, Elektrotehnički aspekti telekomunikacijske opreme
Oznaka faze: 95.99 - povlačenje HRN
Glasilo (rasprava): HZN Glasilo 2/2012 ()
Glasilo (objava): HZN Glasilo 6/2013 ()
Glasilo (povlačenje): HZN e-Glasilo 7/2022 ()
Način prihvaćanja: pr - prihvaćanje strane norme u izvorniku
Cijena #1: Cijena: 41,00 € | Jezik: en | Cjenovni razred: G | Broj stranica: 28
Izvornik: EN 50600-1:2012
Zamjenjena s: HRN EN 50600-1:2019

Obrazac za naručivanje normativnih dokumenata i/ili publikacija (obrazac ob.025-2):

PREUZMITE (DOC)   PREUZMITE (PDF) 

Prijava korisnika

Mrežna stranica koristi kolačiće (cookies). Kolačiće upotrebljavamo kako bismo personalizirali sadržaj i oglase, omogućili značajke društvenih medija i analizirali promet. Isto tako, podatke o vašoj upotrebi naše web-lokacije dijelimo s partnerima za društvene medije, oglašavanje i analizu, a oni ih mogu kombinirati s drugim podacima koje ste im pružili ili koje su prikupili dok ste upotrebljavali njihove usluge. Nastavkom korištenja naših internetskih stranica vi prihvaćate našu upotrebu kolačića. Polica privatnosti.