Hrvatski normativni dokument

HRN EN 61010-2-081:2015

Sigurnosni zahtjevi za mjernu, upravljačku i laboratorijsku električnu opremu -- Dio 2-081: Posebni zahtjevi za automatsku i poluautomatsku laboratorijsku opremu za analize i druge namjene (IEC 61010-2-081:2015; EN 61010-2-081:2015)

Oznaka: HRN EN 61010-2-081:2015
Naslov (HR): Sigurnosni zahtjevi za mjernu, upravljačku i laboratorijsku električnu opremu -- Dio 2-081: Posebni zahtjevi za automatsku i poluautomatsku laboratorijsku opremu za analize i druge namjene (IEC 61010-2-081:2015; EN 61010-2-081:2015)
Naslov (EN): Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 2-081: Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes (IEC 61010-2-081:2015; EN 61010-2-081:2015)
Područje primjene (EN): <span style='color:red' >NEW! </span > IEC 61010-2-081:2015 is available as <a href=http://webstore.iec.ch/webstore/webstore.nsf/Artnum_PK/9999966559?opendocument >IEC Standards+ 61010-2-081:2015 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.


IEC 61010-2-081:20 15 applies to automatic and semi-automatic laboratory equipment for analysis and other purposes. Automatic and semi-automatic laboratory equipment consists of instruments or systems for measuring or modifying one or more characteristics or parameters of samples, performing the complete process or parts of the process without manual intervention. Equipment forming part of such a system is within the scope of this standard. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision and includes the following signif icant changes from the first edition, as well as numerous other changes:

- excluded IEC 61010-2-101 (IVD Equipment) from scope. This separates IEC 61010-2-081 and IEC 61010-2-101 equipment;

- added biological risks symbol to Table 1 in Clause 5;

- added requirement for statement on hazardous substances and gases in Instructions for Use to Clause 5;

- Added marking requirement for flow direction to Clause 5;

- added requirement for OPERATOR maintenance instructions to Clause 7;

- excluded equipment whose size and weight make unintentional movement unlikely from drop test in Clause 8;

- added requirement for biohazard marking to Clause 13;

- added requirement for interlock systems containing electric/electronic or programmable components to Clause 15.

It has the status of a group safety publication in accordance with IEC Guide 104.
Izdanje: 2
ICS: 19.080 Električna i elektronička ispitivanja
71.040.10 Kemijski laboratoriji. Laboratorijska oprema
Tehnički odbor/pododbor: TU V1, Elektronika 1
Oznaka faze: 95.99 - povlačenje HRN
Glasilo (rasprava): 1/2013 ()
Glasilo (objava): 2/2015 ()
Glasilo (povlačenje): 8/2023 ()
Način prihvaćanja: pr - prihvaćanje strane norme u izvorniku
Cijena #1: Cijena: 29,00 € | Jezik: en | Cjenovni razred: D | Broj stranica: 14
Izvornik: EN 61010-2-081:2015
Zamjenjuje: HRN EN 61010-2-081:2002
Zamjenjena s: HRN EN IEC 61010-2-081:2020

Obrazac za naručivanje normativnih dokumenata i/ili publikacija (obrazac ob.025-2):

PREUZMITE (DOC)   PREUZMITE (PDF) 

Prijava korisnika

Mrežna stranica koristi kolačiće (cookies). Kolačiće upotrebljavamo kako bismo personalizirali sadržaj i oglase, omogućili značajke društvenih medija i analizirali promet. Isto tako, podatke o vašoj upotrebi naše web-lokacije dijelimo s partnerima za društvene medije, oglašavanje i analizu, a oni ih mogu kombinirati s drugim podacima koje ste im pružili ili koje su prikupili dok ste upotrebljavali njihove usluge. Nastavkom korištenja naših internetskih stranica vi prihvaćate našu upotrebu kolačića. Polica privatnosti.