HRN EN ISO 10993-17:2023

Biološka procjena medicinskih uređaja -- 17. dio: Toksikološka procjena rizika za sastavnice medicinskih uređaja (ISO 10993-17:2023; EN ISO 10993-17:2023)

Oznaka: HRN EN ISO 10993-17:2023
Naslov (HR): Biološka procjena medicinskih uređaja -- 17. dio: Toksikološka procjena rizika za sastavnice medicinskih uređaja (ISO 10993-17:2023; EN ISO 10993-17:2023)
Naslov (EN): Biological evaluation of medical devices -- Part 17: Toxicological risk assessment of medical device constituents (ISO 10993-17:2023; EN ISO 10993-17:2023)
Područje primjene (EN): This document specifies the process and requirements for the toxicological risk assessment of medical device constituents. The methods and criteria used to assess whether exposure to a constituent is without appreciable harm are also specified. The toxicological risk assessment can be part of the biological evaluation of the final product, as described in ISO 10993-1.
The process described in this document applies to chemical characterization information obtained in line with ISO 10993-18. When a toxicological risk assessment of either the compositional information or analytical chemistry data (e.g. extractable data or leachable data) are required to determine whether the toxicological risks related to the constituents are negligible or tolerable.
The process described in this document is not intended to apply to circumstances where the toxicological risk has been estimated by other means, such as:
—    constituents, excluding cohort of concern or excluded chemicals, that are present in or extracted from a medical device at an amount representative of patient exposure below a relevant, toxicologically-based reporting threshold (see applicable requirements in ISO 10993-18:2020, Annex E and ISO/TS 21726);
—    a new or changed medical device for which chemical or biological equivalence has been established with an existing biocompatible or clinically established medical device (see applicable requirements in ISO 10993-18:2020, Annex C).
The process described in this document is also not applicable to:
—    medical device constituents that do not contact the body (e.g. in vitro diagnostics);
—    biological risks associated with physical interactions of the medical device with the body (i.e. application of mechanical forces, energy or surface morphology, etc.), provided that the chemical exposure is not changed;
—    active pharmaceutical ingredients of device-drug combination products or biologic components of device-biologic combination products as additional regulatory considerations can apply;
—    exposure to a particular constituent that arises from sources other than the device, such as food, water or air.
Izdanje: 3
ICS: 11.100.20 Biološko vrednovanje medicinskih proizvoda
Tehnički odbor/pododbor: TO 555, Medicinski proizvodi
Oznaka faze: 60.60 - HRN dostupan
Glasilo (rasprava): HZN e-Glasilo 12/2021 ()
Glasilo (objava): HZN e-Glasilo 12/2023 ()
Način prihvaćanja: pr - prihvaćanje strane norme u izvorniku
Cijena #1: Cijena: 60,00 € | Jezik: en | Cjenovni razred: M | Broj stranica: 73
Izvornik: EN ISO 10993-17:2023
Zamjenjuje: HRN EN ISO 10993-17:2010
Direktiva/Uredba: (EU) 2017/745

Obrazac za naručivanje normativnih dokumenata i/ili publikacija (obrazac ob.025-2):

PREUZMITE (DOC)   PREUZMITE (PDF) 

Prijava korisnika

Mrežna stranica koristi kolačiće (cookies). Kolačiće upotrebljavamo kako bismo personalizirali sadržaj i oglase, omogućili značajke društvenih medija i analizirali promet. Isto tako, podatke o vašoj upotrebi naše web-lokacije dijelimo s partnerima za društvene medije, oglašavanje i analizu, a oni ih mogu kombinirati s drugim podacima koje ste im pružili ili koje su prikupili dok ste upotrebljavali njihove usluge. Nastavkom korištenja naših internetskih stranica vi prihvaćate našu upotrebu kolačića. Polica privatnosti.